PRODUCTS

FM Starpoint (channels spacing > 1.5Mhz)

FM Starpoint, Triple coaxial filters Combiners

Made of aluminum, silvered copper and PTFE. They are composed of two or more cavity filters connected together by rigid lines, so we will have all inputs selective. It is therefore necessary , in order, knowing all the frequencies of use.

Gallery

Label Italy FDT/2000S fm combiners starpoint 1.5 mhz

Technical Data (see Recommendations)


DUPLEXERS ( FDT/403S MODEL RACK 19″ ):

FDT/403S FDT/2000S FDT/2000S-H FDT/4000S FDT/6000S FDT/10000S
FREQ. RANGE 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz
IMPEDANCE 50 Ohm 50 Ohm 50 Ohm 50 Ohm 50 Ohm 50 Ohm
V.S.W.R. <1.15:1 <1.15:1 <1.15:1 <1.15:1 <1.15:1 <1.15:1
ATTENUATION < 0.8db < 0.6db < 0.6db < 0.5db < 0.5db < 0.5db
ISOLATION BETWEEN CHANNELS
35db typical 35db typical 35db typical 35db typical 35db typical 35db typical
WORKING TEMPERATURE 10-40° 10-40° 10-40° 10-40° 10-40° 10-40°
CONNECTOR IN N N 7/16 7/16 7/8 7/8
CONNECTOR OUT N 7/16 7/8 7/8 1+5/8 1+5/8
POWER 2X200W 2X800W 2X1.2KW 2X2KW 2X3KW 2X5KW
WEIGHT 31 Kg 32 Kg 34 Kg 52 Kg 60 Kg 90 Kg
DIMENSIONS (cm) 80x49x26 130x41x40 130x41x40 130x60x41 130x60x41 130x73x70

 


TRIPLEXERS ( FTT/603S MODEL RACK 19″ – 12U ):

FTT/3000S FTT/3000S-H FTT/4500S FTT/7500S
FREQ. RANGE 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz 87.5 – 108Mhz
IMPEDANCE 50 Ohm 50 Ohm 50 Ohm 50 Ohm
V.S.W.R. <1.15:1 <1.15:1 <1.15:1 <1.15:1
ATTENUATION  < 0.6db < 0.6db < 0.5db < 0.5db
ISOLATION BETWEEN CHANNELS  35db typical 35db typical 35db typical 35db typical
WORKING TEMPERATURE 10-40° 10-40° 10-40° 10-40°
CONNECTOR IN N 7/16 7/16 7/8
CONNECTOR OUT 7/16 7/8 1+5/8 1+5/8
POWER 3X500W 3X1KW 3X1.5KW 3X2.5KW
WEIGHT  60 kg 61 Kg 80 Kg 81 Kg
DIMENSIONS (cm)  130x62x40 130x62x40 130x62x60 130x62x60



QUADRIPLEXERS :

FQT/4000S FQT/4000S-H
FREQ. RANGE 87.5 – 108Mhz 87.5 – 108Mhz
IMPEDANCE 50 Ohm 50 Ohm
V.S.W.R. <1.15:1 <1.15:1
ATTENUATION < 0.6db < 0.6db
ISOLATION BETWEEN CHANNELS  35db typical 35db typical
WORKING TEMPERATURE 10-40° 10-40°
CONNECTORI IN N 7/16
CONNECTOR OUT 7/8 1+5/8
POWER 4x500W 4x1KW
WEIGHT 74 Kg 75 Kg
DIMENSIONS (cm) 130x90x42 130x90x42

Theory

Price & Info

    Pursuant to art. 13 and 14 of EU Regulation 2016/679 of 27 April 2016 we inform you that as Data Controllers we will process all the information you have entered using manual, IT and telematic methods, for purposes instrumental to the request itself.



    Peak FM power calculation in multi-frequency systems

    The output power of an FM transmitter is basically stable. When two transmitters of different frequencies are combined together, the RF peak voltage will be higher than usually thought.

     

    Supposing to use a 5kW transmitter terminated with a 50 ohm load we will have:
    P = V2 / R
    V = √ (P x R) = √ (5000 x 50) = 500Vrms
    The peak voltage will be √2 x 500V = 707V peak.

     

    By combining two 5kW transmitters in a single output to be sent to the antenna system, the individual voltages must be added together , then doubled, resulting in 1000Vrms or 1414V peak.

     

    The comparison with a single 10kW transmitter, that is the simple algebraic sum of 5 + 5kW, they generate a voltage of 707Vrms or 1000V peak, which however does not correspond to the previous calculation of the two combined transmitters.

     

    To obtain the value of the equivalent power that produces a voltage of 1000Vrms we will have:
    P = 10002 / 50 = 20kW
    We have therefore that the equivalent power of the combination of 5 + 5kW transmitters will produce the equivalent effect of a single 20kW transmitter and not a 10kW transmitter as is often erroneously taken into account.

     

    In the case of four combined 5kW transmitters they will supply the antenna 4x500V = 2000Vrms.
    However, by applying the formula we find that this voltage is equivalent to a single 80kW transmitter and not 5kWx4 = 20kW !

     

    The following formula can therefore be used for transmitters of same power:
    Total peak power = Sum of TX powers x number of transmitters

     

    As more transmitters are added, the peak voltage will rise rapidly. This peak voltage is fundamental, especially at high powers with multiple transmitters of different frequencies. The addition of another transmitter is not simply an additional power load. The increase in voltages within the transmission and antenna lines can be significant. If impedance matching is less than perfect, the VSWR will create an even higher peak value.

     

    Coaxial cables that may have been compromised due to humidity or other are more likely to accentuate the problems of higher peak voltage. In the same way, if the antenna is stressed with a power close to its maximum limit, using it with more frequencies, it is very likely a temporary increase in the VSWR, for example during the formation of ice that could start a series of faults in the cables and in the power dividers.

     

     

    Calculation of nominal power of cables

    Cable specifications often provide assessments at various frequencies, but not always at the frequency of interest. Here is a simple formula to obtain from a maximum power expressed at a certain frequency a corresponding to a different frequency:
    P2 = P1 / √ (F2 / F1)
    P1 = known nominal power
    P2 = nominal power at the second frequency

     

    For example, if the cable (or connector) has a nominal power of 5kW at 20MHz, it is possible to calculate its nominal power at 100MHz.
    P2 = 5000 / √ (100/20) = 2236 watt

     

    We must not forget that the maximum power borne by the coaxial cables is typically considered for an ambient temperature of no more than 40 ° but unfortunately the cables are outside and usually black, during the day they therefore undergo a strong overheating even just for effect. of solar radiation. To this is added then that generated by the transit of the RF power that due to the losses due to attenuation transforms part of the RF power into heat.

     

    When deciding to use a radiant system connected to a Multiplexer where there are more frequencies and transmission powers, one must never forget to make a thorough evaluation of the effects on connectors, cables, dividers and antennas.
    The whole radiant system is therefore stressed more than a single transmitter and therefore must be sized correctly also for the overall reliability.
    In this case, a hypothetical failure would result in the loss of service of all the frequencies connected to the radiant system and therefore potentially more serious than in the case of a single transmitter.

     

    It is therefore necessary to provide for a greater safety margin which, for example, can also consist in dividing the radiant system in half and installing two separate feeder cables, so as to be able to use at least half of the antenna even if with less power and therefore not to stop the transmissions and at the same time be able to check the damaged parts.